The following are excerpts from the report summarizing the asbestcs testing and actions taken at the Region 2 building. The testing was performed under contract to the General Services Administration, who had overall responsibility for the maintenance of the building.

On 13 September 2001, air sampling was performed in the building by Phase Contrast Microscopy (PCM), and by Transmission Electron Microscopy (TEM). All of the PCM results were less than 0.01 fibers per cubic centimeter (f/cc), and all of the TEM sample results were No Asbestos Structures Detected (NSD). On 14 September 2001 Stratus Corporation was directed to collect two TEM air samples, and “wipe” samples inside and outside the building lobby, as well as to collect some bulk samples from W A C filters. These samples were collected to determine if asbestos fibers are now present within the dust around the area. After consulting with the laboratory, it was decided that the following types of samples would be collected:

1. Vacuum Samples - These are samples where a normal aisbestos air sampling cassette is attached to a pump, and used like a small vacuum cleaner. ... The material collected can then be analyzed for asbestos by Qualitative Polarized Light Microscopy [PLM], and Qualitative Transmission Electron Microscopy [TEM].

2. Tape Samples - This is a sample where the collector uses a piece of clear tape, like scotch tape, to collect the sample. Where surfaces are visibly dirty, the piece of tape is applied to the surface, and then removed. ... The material collected can then be analyzed for asbestos by Qualitative Polarized Light Microscopy [PLM], and Qualitative Transmission Electron Microscopy [TEM].

3. Filter Samples - These samples are generated by cutting a piece of filter material out of the HVAC unit in the building and placing it in a plastic bag for delivery to the laboratory. The material collected can then be analyzed for asbestos by Qualitative Polarized Light Microscopy [PLM], and Qualitative Transmission Electron Microscopy [TEM|.

On 14 September 2001, two dust samples were collects outside the building entrance, and three samples were collected inside the lobby. The initial TEM qualitative analysis did find chrysotile asbestos to be present in the dust at all locations inside, and outside the building.

On 14 September 2001, two tape samples were collected outside the building entrance, and three samples were collected inside the lobby. No asbestos was detected in any of these three samples by PLM qualitative analysis, or by TEM qualitative analysis.

On 14 September 2001, three samples were collected from the HVAC filters. One sample was collected from AC-1, one sample was collected from AC-32, and one sample was collected from AC-31. No asbestos was detected in any of these three samples by PLM qualitative analysis, or by TEM qualitative analysis.

One of the two TEM air samples collected on 14 September 2001, simultaneous to the “wipe” sampling both yielded results of No Asbestos Structures Detected (NSD). The other sample did detect asbestos, as was collected inside the lobby, by the West wall.

-39-

CITY_21MC100_013381588

NYC-WTC_000250768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →