EPA memo on air and dust asbestos testing, Mar 2002

Machine-extracted title · confidence 50%

EPA memo documenting issues with asbestos testing standards post-WTC collapse.

NYC-WTC_000250730–000250772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

After the discovery of asbestos in the lobby of the building, the EPA informed the building management, that the EPA would be cleaning the lobby areas of all the buildings In the area. Additionally, building cleaning personnel also began performing cleaning inside the building lobbies.

On 16 September Stratus was rtsquested to begin a regime of continuous TEM air sampling at the Duane Street entrance, the only operational entrance to the building. initially, two samples were collected outside the Duane Street entrance, and two samples were collected inside the Duane Street entrance. ... On 19 September 2001 an additional two sets of samples were collected, and samples were taken at the air intake location to some HVAC systems at this time.

From 16 September through 19 September 2001, a total of 47 TEM air samples were collected at this site. Except for three samples, all results were No Structures Detected. Two of the other samples were overloaded, and the lab performed a qualitative scan on the sample. This means that particulate matter on the samples prevented the lab from accurately performing an analysis on the sample, so they had to declare it overloaded. The qualitative scan was then performed to see if any asbestos fibers could be found. On both overloaded samples, no asbestos structures were observed.

One sample collected outside the entrance during the morning of 17 September did find asbestos in the sample. The value for this sample was 0.003 structures per cubic centimeter [equivalent to ] 25 structures per square millimeter. This reading is considered a low reading, and would be an acceptable reading for post abatement sampling after an asbestos abatement project.

[Stratus Corporation (October 5, 2001) Asbestos Emergency Monitoring Report at 290 Broadway after the World Trade Center Disaster, Final Report. Made available by EPA Region 2 in response to a January 3, 2002 Freedom of Information Act request by the New York Environmental Law and Justice Project. Posted at http://www.nyenvirolaw.org/PDF/EPA-FOIL-scannedOn-2-27-02.pdf ]

A very different version of these events was contained in a Februar’ 22, 2002 letter to Congressman Nadler from EPA Administrator Whitman:

EPA did not set a more stringent standard of cleanup for these federal buildings, and the lobby cleanup was consistent with the New York City Department of Health advisory. After noting significant amounts of dust tracked into 290 Broadway and 26 Federal Plaza by workers responding at the World Trade Center, the General Services Administration asked EPA to clean the lobbies. The work was done by EPA contractors using HEPA vacuums already operating in the same area. As outlined in the enclosure, EPA collected seven air samples at 26 Federal Plaza and six air samples at 290 Broadway, anc found results below levels of concern.

[first attachment to letter follows, full fexf]

USEPA Air Analytical Results from 9/13/01 Sampling Event

26 Federal Plaza: Seven air samples were collected at the 26 Federal Plaza (13*^, 26*'’. 38'*’, 39* floor and in the lobby). The asbestos concentrations ranged from non­ detect to 0.0072 fibers/cc (south lobby). Data results are less than the OSHA Permissible Exposure Limit of 0.1 fibers/cc. 290 Broadway: Six air samples were collected at the 290 Broadway (8*, 22fh, LL- 1, LL-2 and Lobby). The asbestos concentrations ranged from non-detect to 0.0133 fibers/cc (LL-1).

-40-

CITY_21MC100_013381589

NYC-WTC_000250769

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250769Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →