NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Lower Manhattan air quality discussion, 2002

Machine-extracted title · confidence 41%

Correspondence addressing asbestos monitoring data and interpretation of OSHA/EPA findings related to WTC area.

NYC-WTC_000320107–000320110
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

[LNancy Jeffery - Nadler whjte,paper response22702jl.d6c PagegJi

NYC DEP’s Ambient Asbestos Air Sampling Results

NYC DEP obtained 3,540 airborne asbestos samples from a network of monitoring stations around the WTC site. DEP also collected 616 samples at entrances to four schools, and 408 samples from outer boroughs. As of March 6, 2002, of the total 4,564 outdoor air samples obtained and analyzed by DEP, only 9 (0.2%) were above the federal and City standard of 0.01 fibers per cubic centimeter by PCM analysis. Of the analyzed by TEM.......

US Environmental Protection Agency Air Quality Monitoring

The EPA’s level of concern for asbestos for the WTC incident is based on continuous exposure to more than 70 structures per square millimeter for an extended period. In evaluating data from the World Trade Center and the surrounding areas, EPA is using a protective standard under AHERA, the Asbestos Hazard Emergency Response Act, to evaluate the risk from asbestos in the outdoor and indoor air. This is a very stringent standard that is used to determine whether children may re-enter a school building after asbestos has been removed or abated. It is based on assumptions of long-term exposure. EPA has chosen to use this standard, because it is the most stringent and protective, even though it is unlikely that the public will be exposed to asbestos from the World Trade Center site for extended periods of time.

To determine asbestos levels, air filters are collected from monitoring equipment through which air in the school building has passed and viewed through a microscope. The number of structures - material that has asbestos fibers on or in it - is then counted. The measurements must be 70 or fewer structures per square millimeter before children are allowed inside. Levels above 70 structures per square millimeter do NOT imply an immediate health threat. Asbestos exposure becomes a health concern when high concentrations of asbestos fibers are inhaled over a long period. Illness is very unlikely to result from a single, high-level exposure, or from a short period of exposure to lower levels.

EPA obtained and analyzed a total of 6,461 samples for airborne asbestos from monitoring sites throughout Lower Manhattan through February 25, 2002. Of the total, 15 samples (0.23%) were above the EPA’s screening level of 70 structures per square millimeter. (EPA advises that information contained in this database should be considered provisional and may be subject to adjustment upon final analysis).

OSHA Sampling Results as of March 18, 2002

A total of 1144 samples (excluding bulk and blank samples) for asbestos have been taken. From September 13 through September 21, 177 samples were taken in the financial district. Since September 21,2001 sampling focused on

CITY_21MC100_0 03050510

NYC-WTC_000320108

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320108Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000455321

DOH letter explaining asbestos test results in lower Manhattan residences.

Similar indexed content

Compare copies and versions →