NYC-WTC_000320906
Regional WTC asbestos air monitoring data summary with sample counts and results.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Summary of asbestos air monitoring results around Lower Manhattan and site sites.
NYC-WTC_000338034–000338036OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Asbestos Air Monitoring Data Summary for Lower Manhattan WTC Sampling
Totals (for sampling through 01/29/02, in s/mm2) Total Samples 5517 Samples Above Screening Level 15 % Above 0. 27 % Samples Below 5502 Maximum Value (12/04/01); 204.44 Minimum Value: Not Detected Screening Level*; 70 Average All 10.54
■ Samples Above Screening Level - All Lewer Manhattan Sites
BSaraoles Below
1(11% The level of concern for asbestos is based on continuous exposure to more than 70 structures per square millimeter for an extended period. In evaluating data from the World Trade Center and the surrounding areas, EPA is using a protective standard under AHERA, the Asbestos Hazard Emergency Response Act, to evaluate the risk from asbestos in the outdoor and indoor air. This is a very stringent standard that is used to determine whether children may re-enter a school building after asbestos has been removed or abated. It is based on assumptions of long-term exposure, EPA has chosen to use this standard, because it is the most stringent and protective, even though it is unlikely that the public will be exposed to asbestos from the World Trade Center site for extended periods of time.
To determine asbestos levels, air filters are collected from monitoring equipment through which air in the school building has passed and viewed through a microscope. The number of structures - material that has asbestos fibers on or in it - is then counted. The measurements must be 70 or fewer structures per square millimeter before children are allowed inside.
There is also a federal standard for asbestos exposure under OS HA, the Occupational Safety and Health Act, which is used to protect workers on-the-job. The standard is .1 fiber per cubic centimeter averaged over an eight-hour day. To be as protective as possible, EPA is using the school re-entry standard in tests around the World Trade Center. Levels above 70 structures per square millimeter do NOT imply an immediate health threat. Asbestos exposure becomes a health concern when high concentrations of asbestos fibers are inhaled over a long period. Illness is very unlikely to result from a single, high-level exposure, or from a short period of exposure to lower levels.
CITY_21MC100_008980636
NYC-WTC_000338034
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000320906
Regional WTC asbestos air monitoring data summary with sample counts and results.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320987
Asbestos air monitoring data summary for Regional WTC through 01/29/02.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320969
Asbestos air monitoring data summary for World Trade Center site through 01/29/02.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320951
Asbestos air monitoring data summary for Regional WTC sites through 01/29/02, showing counts and percent above thresholds.
1 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320926
Regional asbestos monitoring data through 01/29/02 with counts and notes on below/above background.
1 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320920
Asbestos monitoring data for Regional WTC, including counts and percent above background.
1 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320944
Asbestos data summary for Regional WTC sites through 01/29/02.
1 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208357
Summary statistics for asbestos air monitoring data collected in the regional World Trade Center area through January 2002.
1 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279319
Asbestos air monitoring data summary for Regional WTC sampling through Jan 29, 2002.
1 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320943
Asbestos monitoring data summary for Staten Island Landfill WTC through 01/29/02.
1 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353712
Data summary of asbestos air monitoring with % above and screening values for Staten Island landfill.
1 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320925
Asbestos monitoring data for Staten Island Landfill WTC area, with counts and notes.
1 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000320934
Asbestos air monitoring data summary for Lower Manhattan WTC sites through 01/29/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199699
Summary of asbestos air monitoring data for Lower Manhattan World Trade Center sites through January 29, 2002, with statistical analysis.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243046
Asbestos air data summary around WTC site through 01/29/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320922
Asbestos data summary through 01/29/02 with counts and level-of-concern narrative.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320995
Asbestos air monitoring data summary with sample counts and color-coded status.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320985
Asbestos air monitoring data summary for Lower Manhattan WTC through 01/29/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000320906
Regional WTC asbestos air monitoring data summary with sample counts and results.
Similar indexed content
Asbestos air monitoring data summary for Regional WTC through 01/29/02.
Similar indexed content
Asbestos air monitoring data summary for World Trade Center site through 01/29/02.
Similar indexed content
Asbestos air monitoring data summary for Regional WTC sites through 01/29/02, showing counts and percent above thresholds.
Similar indexed content
Regional asbestos monitoring data through 01/29/02 with counts and notes on below/above background.
Similar indexed content