EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L: EPA refusal to use electron microscopesfor dust testing - 234

assessment for Libby where the same concentrations, occurring less frequently, were the basis for placing Libby on the Superfund list;

Dusts from the collapse of the WTC present more risk than soils in Libby because they are a finely divided surface dust with no vegetation to hold them in place. Although the dusts from the WTC have now been removed to some extent, we do not know how effective the removal is to date, or whether dusts have been effectively removed from roofs, which have a larger surface area than the streets in Lower Manhattan. ... [Jenkins, 3/11/02]

4/30/02 This memorandum discusses side-by-side testing of the same dust samples ("bulk dust") from WTC fallout. Two different test methods were used. One method is transmission electron microscopy (TEM), which is very sensitive, detecting the very thin asbestos fibers that are known to predominate in WTC dusts, and also capable of detecting fibers at levels as low as 0.0001%. The other method is polarized light microscopy (PLM), using a standard light microscope, which cannot detect the thin fibers found in WTC dusts, and which can only reliably detect 1% or higher levels of asbestos. TEM is a much more sensitive method than PLM.

After the WTC collapse, EPA Region 2 only used the less sensitive method, PLM, for bulk dusts in Lower Manhattan. This is despite the fact that official EPA guidance requires the use of the more sensitive TEM methods when thin asbestos fibers are present, such as is the case for WTC fallout. EPA regulations and guidance require determining if any asbestos is present in dusts and other emissions from the original asbestos containing materials, by using the sensitive TEM method which can detect asbestos at concentrations much lower than 1%.

EPA Policy requires TEM for bulk dusts if small asbestos fibers present

Even if all personnel in Region 2 had never encountered a situation where there was a need to test dust for asbestos, then Region 2 was still obligated to follow the official EPA policy guidance that requires the use of TEM methods for dusts. EPA advises that TEM should be used when the asbestos fibers are thin, since they cannot be detected by PLM. The fact that WTC dust is predominantly thin fibers that cannot be detected by PLM was discussed earlier. The following are excerpts from EPA's 1994 Federal Register notice which instituted the policy to use TEM;

The Occupational Safety and Health Administration (OSHA) also recommends the use of the more sensitive TEM tests for settled bulk dusts instead of PLM. The following are the relevant parts of the OSHA regulations:

Comparison of results of side-by-side TEM and PLM tests on the same samples

The following table compares the results of TEM and PLM tests for the same samples of bulk dusts from the WTC collapse, tar and soils. More information on the materials and sampling is given after the table.

NYC-WTC_000251390

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251390Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →