Asbestos air test results, 250 [name] Ave

Machine-extracted title · confidence 32%

Summary of asbestos air testing results; November 14, 2001 sampling in building and residences.

NYC-WTC_000367211–000367214
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SiimtJia/y of A sbes/os Sampling Results Page 3 of 4 Address: 250 Soiillt Rnd Date sampled- November 14, 2001

ASBETOS DUST TEST RESULTS

The dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) PLM is used to define asbestos containing material in dust and debris A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method The PLM method only counts the larger asbestos fibers Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples

Asbestos was found in low levels in the courtyard outside the building DOH and City Department of Environmental Protection (DEP) inspected the building after the sampling was conducted to determine if further action was warranted Additional testing and an assessment of the debris in the garden troughs in the courtyard indicated that it needed to be cleaned by an asbestos abatement contractor The building owner hired a contractor and the debris was abated in accordance with DEP asbestos abatement regulations. Low levels of asbestos were also found in the dust on a window sill of the building The concentration of asbestos found in this sample did not warrant the use of an asbestos abatement contractor since it was less than 1% No asbestos fibers were found in the dust samples collected from the floor in the common area or two residences

Fibrous materials in dust found by PLM analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis The laboratory analyst will count the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust samples

Results of Polarized Light Microscopy (PLM) testing of 250 South End Avenue, November 14, 2001 Area Sampled Outside Outside* Common Residence 1 Residence 2 Residence 3** Sample Numbers SA-C-2 SA-C-2B VA-C-2 VA-RI-2 VA-R2-2 VA-R3-2

Asbestos fibers (%) <1% 1.3 % None None None < 1 % Detected Detected Detected * The outdoor courtyard was resampled on December 6“ to confinn the presence of asbestos. ** This sample was settled dust from a living room window sill. The oilier interior dust samples were from the floor

Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust samples that showed asbestos content by PLM as less than 1% TEM analysis is very specific, can detect smaller fibers of asbestos and is subject to less interference This analysis was done to confirm the PLM findings of no asbestos found However, TEM analysis is not used for regulatory purposes for dust samples

CITY_DEP_WORBY_CANNATA_SUBP_000004036

NYC-WTC_000367213

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367213Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →