EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L: EPA refusal to use electron microscopesfor dust testing - 233

well as bright field microscopes...,

When electron mio-oscopy was applied to asbestos analysis, hundreds of fibers were discovered present too small to be visible in any light microscope [such as PLM]. There are two different types of electron microscq)e used for asbestos analysis; Scanning Electron Microscope (SEM) and Transmission Electron Microscc^e (TEM). Scanning Electron Microscopy is useful in identifying minerals. The SEM can provide two of the three pieces of information required to identify fibers by electron microscopy: morphology and chemistry. The third is structure as determined by Selected Area Electron Diffraction - SAED which is performed in the TEM. Although the resolution of the SEM is sufficient for very fine fibers to be seen, accuracy of chemical analysis that can be performed on the fibers varies with fiber diameter in fibers of less than 0.2 um diameter. The TEM is a powerfill tool to identify fibers tcx) small to be resolved by light microscopy and should be used in conjunction with this method when necessary. The TEM can provide all three pieces of information required for fiber identification. Most fibers thicker than 1 um can adequately be defined in the light microscope.

The light microscope remains as the best instrument for the determination of mineral type. This is because the minerals under investigation were first described analytically with the light microscope. It is inexpensive and gives positive identification for most samples analyzed. Further, when optical tediniques [PLM1 are inadequate, there is ample indication that alternative techniques fTEM and SEMI should be used for complete identification of the sample.

[emphasis added] [Code of Federal Regulations posted at either OSHA site at http-.//www.osha.gov/OshStd_toc/OSHA_Std_toc.html or http;//www.access.gpo.gov/nara/cfr/cfr-table-search.html ]

Settled dusts in Lower Manhattan had higher asbestos than soils in Libby, MT Region 2 claims that asbestos levels are “low" in Manhattan dust

The settled dusts in Lower Manhattan tested in the early days after the WTC collapse had higher concentrations of asbestos than outdoor soils in the town of Libby, Montana, the Superfund site.

Around 35% of the samples of bulk dust taken in Lower Manhattan in the first few days after the collapse exceeded the 1% level.

[Mugdan, Walter E. (January 25, 2002) Environmental law issues raised by terrorist events. Speech before the NY Bar Association, NYC. Walter Mugdan is Regional Counselfor EPA Region 2.]

There was a higher percentage of samples that had over 1 % asbestos from the WTC than soils in Libby, Montana, the town that is a Superfund site. The concentrations of asbestos, when the asbestos was found, are the same in Libby as in Lower Manhattan. In Libby, soils from yards from residences, etc., are being removed because of the asbestos hazard they pose.

Region 2 Counsel has claimed that the asbestos concentration in WTC dusts was low and not a health hazard. This directly contradicts the findings of the extensive risk

NYC-WTC_000251389

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251389Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →