determine asbestos at concentrations less than 1%, and because this method cannot detect the thinner, smaller asbestos fibers, such as chrysotile.

[NESHAP] 40 CFR § 61

§61.155 Standard for operations that convert asbestos-containing waste material into nonasbestos (asbestos-free) material. Each owner or operator of an operation that converts RACM and asbestos­ containing waste material into nonasbestos (asbestos free) material shall: (a) Obtain the prior written approval of the Administrator to construct the facility.... In addition to the information requirements of §61.07(b)(3), a (i) Description of waste feed handling and temporary storage, (ii) Description of process operating conditions, (iii) Description of the handling and temporary storage of the end product, (iv) Description of the protocoIto be followed when analyzing output materials by transmission electron microscopy.

(b) Conduct a start-up performance test. Test results shall include; (1) A detailed description of the; types and quantities of nonasbestos material, RACM, and asbestos-containing waste material processed, e.g., asbestos cement products, friable asbestos insulation, plaster, wood, plastic, wire, etc. Test feed is to include the full range of materials that will be encountered in actual operation of the process. (2) Results of analyses, using polarized light microscopy, that document the asbestos content of the wastes processed. (3) Results of analyses, using transmission electron microscopy ITEMI, that document that the output materials are free of asbestos. Sam pies for analysis are to be collected as 8-hour composite samples (one 200-gram (7-ounce) sample per hour), beginning with the initial introduction of RACM or asbestos-containing waste material and continuing until the end of the performance test.

(c) During the initial 90 days of operation ... (2) Monitor input materials to ensure that they are consistent with the test feed materials described during start-up performance tests in paragraph (b)(1) of this section. (3) Collect and analyze samples, taken as 10-day composite samples (one 200-gram (7-ounce) sample collected every 8 hours of operation) of all output material for the presence of asbestos. Composite samples miay be for fewer than 10 days. Transmission electron microscopy (TEM) shall be used to analyze the output material for the presence of asbestos. During the initial 90-day period, all output materials must be stored on-site until analysis shows the material to be asbestos-free or disposed of as asbestos- containing waste material according to §61.150.... (h) Nonasbestos (asbestos-free) output material is not subject to any of the provisions of this subpart. Output materials in which asbestos is detected, or output materials produced when the operating parameters deviated from those established during the startup performance testing, unless shown by TEM analysis to be asbestos-free, shall be considered to be asbestos-containing waste and shall be handled and disposed of according to §§61.150 and 61.154 or reprocessed while all of the established operating parameters are being met. [emphasis added]

[The Code of Federal Regulations are available from most larger libraries, all law libraries, and also online at: http://www.access.gpo.gov/nara/cft/index.html, or for EPA-only (faster) at http://www.epa.gov/epahome/cfr40.htm ]

-33-

CITY_21MC100_013381582

NYC-WTC_000250762

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250762Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →