EPA memo on air and dust asbestos testing, Mar 2002

Machine-extracted title · confidence 50%

EPA memo documenting issues with asbestos testing standards post-WTC collapse.

NYC-WTC_000250730–000250772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OSHA regulations recommend TEM analyses of settled, bulk dusts

The Occupational Safety and Health Administration (OSHA) also recommends the use of sensitive TEM analyses for settled, bulk dusts and other solid asbestos materials. The following are the relevant OSTIA regulations:

[OSHA] 29 CFR 1926.1101 Appendix A -Polarized Light Microscopy of Asbestos - Non-Mandatory

Light microscopy has been used for well over 100 years for the determination of mineral species. This analysis is carried out using specialized polarizing microscopes [PLM] as well as bright field microscopes. ...

When electron microscopy wa,s applied to asbestos analysis, hundreds of fibers were discovered present too small to be visible in any liqht microscope [such as PLM1. There are two different types of electron microscope used for asbestos analysis: Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM), Scanning Electron Microscopy is useful in identifying minerals. The SEM can provide two of the three pieces of information required to identify fibers by electron microscopy: morphology and chemistry. The third is structure as determined by Selected Area Electron Diffraction - SAED which is performed in the TEM. Although the resolution of the SEM is sufficient for very fine fibers to be seen, accuracy of chemical analysis that can be performed on the fibers varies with fiber diameter in fibers of less than 0.2 urn diameter. The TEM is a powerful tool to identify fibers too small to be resolved by liqht microscopy and should be used in conjunction with this method when necessary. The TEM can provide all three pieces of information required for fiber identification. Most fibers thicker than 1 um can adequately be defined in the light microscope.

The light microscope remains as the best instrument for the determination of mineral type. This is because the minerals under investigation were first described analytically with the light microscope. It is inexpensive and gives positive identification for most samples analyzed. Further, when optical techniques [PLM1 are inadequate, there is ample indication that alternative techniques [TEM and SEMI should be used for complete identification of the sample, [emphasis added]

[Code of Federal Regulations posted at either OSHA site at http://www.osha.gov/OshStd toc/OSHA Std toc.html or http:/Avww.access.gpo.qov/nara/cfr/cfr-table-search.html 1

Settled dusts in Lower Manhattan had higher asbestos than soils in Libby, MT

Region 2 claims that asbestos levels are "low" in Manhattan dust

The settled dusts in Lower Manhattan tested in the early days after the WTC collapse had higher concentrations of asbestos than outdoor soils in the town of Libby, Montana, the Superfund site.

-34-

CITY_21MC100_013381583

NYC-WTC_000250763

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250763Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →