NYC 9/11 Public Portal Document

K: ]% asbestos in settled dust - 219

Decontamination of Area Surrounding Demolition Site If a site assessment detects contamination of soil surrounding a demolition site, the site must be cleaned up to background levels of asbestos contamination. Alternatively, the site may be operated in accordance with section 61.154 (Standard for active waste disposal sites) and closed in accordance with section 61.151 (Standard for inactive waste disposal sites for asbestos mills and manufacturing and fabricating iterations). However, according to 40 CFR 61.05, the establishment of an active waste site requires prior approval from EPA or the delegated State program. To clean up the site to background levels, it will probably be necessary to remove all the asbestos contaminated soil. The contaminated soil should be treated and disposed of as asbestos-containing waste material.... [US EPA (1994) Asbestos/NESHAP Demolition Decision Tree. EPA Manufacturing, Energy, and Transportation Division, Office of Compliance. Available from the EPA OPPTS Ombudsman's office]

Under both the asbestos NESHAP and AHERA regulations, ZERO emissions of asbestos-containing dusts are required, not "emissions of dusts containing less than 1% asbestos."

In the collapse of the WTC, the airborne dusts are also analogous to the dust emissions from the transport or disposal of asbestos wastes under AHERA or the NESHAP. From the above section, they are probably more analogous to contaminated soils around a demolition site. They are not, however, as Region 2 is trying to argue, analogous to the original building materials themselves where the 1% rule applies..

The requirement for zero emissions, not emissions of dusts containing less than 1% asbestos, is made clear in the following guidance and regulations;

[NESHAP] Q; Is there a numeric emission limit for the release of asbestos fibers during renovations or demolitions in the asbestos NESHAP regulation? A: No, the Asbestos NESHAP relating to demolitions or renovations is a work practice standard. This means that it does not place specific numerical emission limitations for asbestos fibers on asbestos demolitions and removals. Instead, it requires specific actions be taken to control emissions. However, the Asbestos NESHAP does specify zero visible emissions to the outside air from activity relating to the transport and disposal of asbestos waste. [US EPA. Common Questions on the Asbestos NESHAP. Posted at http://www.epa.gov/opptintr/asbestos/neshap.pdf ]

[NESHAP] 40 CFR §61.144 Standard for manufecturing.__ (b) Standard. Each owner or operator of any of the manufacturing operations to which this section applies shall either: (1) Discharge no visible emissions to the outside air from these operations or from any building or structure in which they are conducted or from any other fugitive sources; or (2) Use the methods specified by §61.152 to clean emissions from these operations containing particulate asbestos material before they escape to, or are vented to, the outside air. (3) Monitor each potential source of asbestos emissions from any part of the manufacturing facility, including air cleaning devices, process equipment, and buildings housing material processing and handling equipment...

[AHERA] 40 CFR § 763 - Appendix D to Subpart E - Transport and Disposal of

NYC-WTC_000251375

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251375Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →