vented to, the outside air. (3) Monitor each potential source of asbestos emissions from any part of the manufacturing facility, including air cleaning devices, process equipment, and buildings housing material processing and handling equipment...

[AHERA] 40 CFR § 763 - Appendix D to Subpart E - Transport and Disposal of Asbestos Waste For the purposes of this appendix, transport is defined as all activities from receipt of the containerized asbestos waste at the generation site until it has been unloaded at the disposal site. Current EPA regulations state that there must be no visible emissions to the outside air during waste transport. However, recognizing the potential hazards and subsequent liabilities associated with exposure, the following additional precaution.s are recommended. [emphasis added]

[The Code of Federal Regulations are available from most larger libraries, all law libraries, and also online at: http://www.access.gpo.qov/nara/cfr/index.html, or for EPA-only (faster) at http://www.epa.gov/epahome/cfr40.htTi ]

The regulations themselves define the building materials as those containing 1% or more asbestos, and the dusts emanating from these materials are defined as emissions or debris. The 1% regulations do not apply to the emissions.

[AHERA] 40 CFR §763.83 Definitions. For purposes of this subpart: Act means the Toxic Substances Control Act (TSCA), 15 U.S.C. 2601, et seq. ... Asbestos-containing mete rial (ACM) when referring to school buildings means any material or product which contains more than 1 percent asbestos. Asbestos-containing building material (ACBM) means surfacing ACM, thermal system insulation ACM, or miscellaneous ACM that is found in or on interior structural members or other parts of a school building. Asbestos debris means pieces of ACBM that can be identified by color, texture, or composition, or means dust, if the dust is determined by an accredited inspector to be ACM. ... Fiber release episode means any uncontrolled or unin tentional disturbance of ACBM resulting in visible emission. 4. "Major fiber release episode" means any uncontrolled or unintentional disturbance of ACBM, resulting in a visible emission, which involves the falling or dislodging of more than 3 square or line ar feet of friable ACBM. 5. "Minor fiber release episode" means any uncontrolled or unintentional disturbance of ACBM, resulting in a visible emission, which involves the falling or dislodging of 3 square or linear feet or less of friable ACBM.

[NESHAP] 40 CFR §61.141 Definitions. ... Category I nonfriable asbestos-containing material (ACM) means asbestos-containing packings, gaskets, resilient floor covering and asphalt roofing products containing moret than 1 percent asbestos ... Category II nonfriable ACM means any material, excluding Category I nonfriable ACM, containing more than 1 percent asbestos ... Fugitive source means any source of emissions not controlled by an air pollution control device. ... Visible emissions means any emissions, which are visually detectable without the aid of instruments, coming from RACM [regulated asbestos containing material] or asbestos-containing waste material, or from any asbestos milling.

-30-

CITY_21MC100_013381579

NYC-WTC_000250759

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250759Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.