The Agency for Toxic Substances and Disease Registry found no studies measuring typical soil background levels of asbestos. From a limited additional literature search, I also found no studies. Thus, I am not able to provide data for typical soil levels or background levels for asbestos. (ATSDR (2000) Toxicological Profile for Asbestos, Centers for Disease Control, ATSDR. Available by calling 1-888-42-ATSDR. At this time, only the final draft version is posted on the internet at www.atsdr.cdc.gov/toxt7rofiles/tp61.html )

Under both the EPA NESHAP and AHERA regulations, ZERO emissions of asbestos-contaminated dusts is required, not emissions containing only 1% asbestos or less

Under both the asbestos NESHAP and AHERA regulations, ZERO emissions of asbestos-containing dusts are required, not “emissions of dusts containing less than 1% asbestos.”

In the collapse of the WTC, the airborne dusts are also analogous to the dust emissions from the transport or disposal of asbestos wastes under AHERA or the NESHAP. From the above section, they are probably more analogous to contaminated soils around a demolition site. They are not, however, as Region 2 is trying to argue, analogous to the original building materials themselves where the 1% rule applies..

The requirement for zero emissions, not emissions of dusts containing less than 1% asbestos, is made clear in the following guidance and regulations:

[NESHAP] Q: Is there a numeric emission limit for the release of asbestos fibers during renovations or demolitions in the asbestos NESHAP regulation?

A: No, the Asbestos NESHAP relating to demolitions or renovations is a work practice standard. This means that it does not place specific numerical emission limitations for asbestos fibers on asbestos demolitions and removals. Instead, it requires specific actions be taken to control emissions. However, the Asbestos NESHAP does specify zero visible emissions to the outside air from activity relating to the transport and disposal of asbestos waste. [emphasis added\

[US EPA. Common Questions on the Asbestos NESHAP. Posted at http://www.epa.gov/opptintr/asbestos/neshap.pdf1

[NESHAP] 40 CFR §61.144 Standard for manufacturing. ... (b) Standard. Each owner or opesrator of any of the manufacturing operations to which this section applies shall either: (1) Discharge no visible emissions to the outside air from these operations or from any building or structure in which they are conducted or from any other fugitive sources; or (2) Use the methods specified by §61.152 to clean emissions from these operations containing particulate asbestos material before they escape to, or are

-29-

CITY_21MC100_013381578

NYC-WTC_000250758

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250758Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →