L: EPA refusal to use electron microscopesfor dust testing - 231

The test method provides clarifications and improvements to the 1982 EPA 'Interim Method for the Determination of Asbestos in Bulk Insulation Samples" (as found in 40 CFR part 763 Appendix A to Subpart F). Specifically, use of the improved method can provide more precise analytical results especially at low asbestos concentrations. enhanced analysis of floor tiles which may contain thin asbestos fibers below the limits of resolution of the polarized light microscope (PLM). and clearer instruction on the analysis of bulk materials, particularly where multiple layers are present.

The 1982 method is limited in that it does not provide guidance for analyzing materials that contain thin (<0.25 micrometers) asbestos fibers. As a consequence, floor tiles which were analyzed according to the 1982 method and for which negative results were reported may actually contain undetected asbestos. At this time EPA does not have data to support identification of other materials which may have thin fibers.

The improved method addresses the thin fiber limitation of the 1982 method by providing directions for using transmission electron microscopy (TEM). The test method includes improved procedures for reducing matrices so that fibers may be made available for microscopic analysis.

In light of the availability of the improved method, EPA recommends that local education agencies (LEAs) use the improved method in place of the 1982 procedures as found in 40 CFR part 763 Appendix A to Subpart F. EPA has made the determination that the improved method is more capable of producing accurate results than the 1982 protocol and thus serves as a preferred substitute method. Further, EPA recommends that LEAs which have PLM laboratory results indicating floor tiles to be non- asbestos-containing (asbestos present in less than or equal to 1 percent) reconsider whether these materials may have thin asbestos fibers.

Before undertaking activities which might trigger asbestos NESHAP requirements, it is recommended that LEAs consider resampling multi-layered materials which have been found to be nonasbestos-containing for AHERA purposes or assume them to be asbestos-containing prior to disturbance according to the guidelines set forth in this current notice, in the January 5, 1994 NESHAP Federal Register notice, and in the improved analytical method to avoid potential violation of the asbestos NESHAP. [emphasis added]

EPA NESHAP regulations require testing by the sensitive TEM method for asbestos- derived wastes to determine if they asbestos free The asbestos-free level is “no asbestos detected by TEM” not 1 %

The NESHAP regulations themselves require the use of transmission electron microscopy (TEM) to determine whether wastes can be considered “asbestos free.” The standard for being asbestos free is not 1%, but instead no detectable asbestos by the most sensitive test method, TEM. The use of polarized light microscopy (PLM) is not sufficient according to the regulations, because this method cannot reliably determine asbestos at concentrations less than 1%, and because this method cannot detect the thinner, smaller asbestos fibers, such as chrysotile.

[NESHAP] 40 CFR § 61 §61.15 5 Standard for operations that convert asbestos-

NYC-WTC_000251387

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251387Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →