NYC 9/11 Public Portal Document
jv/tc residential plan octlS.wpd Page 8 j
****DRAFT*^**
Indoor air sampling for asbestos will be conducted and analyzed using NIOSH mediod 7400. If an
action level is exceeded subsequent filter analysis using NIOSH 7402 to determine if the fibers I
present are asbestos will be conducted. Respirable crystalline silica will be sampled and analyzed
using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size particles will
be conducted using the IONH'"' sampler. The relative amounts (percent weight) of each fraction
present will be detennined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and
calcite using X-ray diffraction (XRD) analysis, and for asbestos using PLM analysis (and TEM
analysis if PLM indicates <1%).
I
Indoor floor dust samples will be collected using EPA ERT SOP for household dust collection.
As much dust as possible will be collected; the area vacuumed will be measured and reported.
Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD.
Asbestos will be anak zycd using PLM ; if <1% if found, TEM analysis will be conducted. The pH
i
of the dust will be tested using EPA SW846 Method 9045C.
2. Exterior
Outdoor air and settled dust sampling will occur in areas adjacent to the residential building being
tested indoors. Sampling will occur concurrent!}' with indoor sampling.
I
Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be
conducted and anah'zed using NIOSH method 7400. If an action level is exceeded subsequent
filter analysis using NIOSH 7402 to determine the amount of asbestos fibers present will be
conducted. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500.
Air sampling for inhalable, thoracic, and respirable size particles will be conducted using the
lOM^*"’ sampler. Tlie relative amounts (percent weight) of each fraction present will be
detennined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using
X-ray diffraction (XRD) analysis, and for asbestos using PLM analysis (and TEM analysis if PLM
indicates <1%). Twelve-hour, continuous, real-time TSP, PMIO and PM 2.5 sampling will be 1J
conducted-again at breathing zone height.
Settled surface dust samples will be collected by scraping visible dust into a glass container. A
minimiun of 25-30 grams of sample is required. Samples will be analyzed for cr}’stalline silica,
gy'psum, mica, fiberglass and calcite using XRD, and for asbestos using PLM analysis (and TEM
analysis if PLM indicates <1%). The pH of tlie dust will be tested using EPA SW846 Metliod
9045C.
8
CITY_21MC100_013489382
NYC-WTC_000250553
OCR can misread numbers and units. Confirm readings against the page image before using them.