NYC 9/11 Public Portal Document
j wtc residential plan oct18.wpd
Samplc/Anahiiciil Methods
Parameter Enyironmcntal.Mcdia Sanipling/Analytical Method Sample Flow/timc Analytical LOD / LOO'
Asbestos I/O” air NIOSI-I 7400, NIOSH 7402 I6L/min-4hr(3840L) 0.010 f/cc (LOQ)
Breathing zone sample height 5 hr (4800L) 0.008 f/cc I
6 hr (5760L) 0.007 f/cc
Total Suspended O air EPA Method # (continuous realtime) 12-hr
Particulates Breathing zone sample height
PM 10 and PM2,5 O air EPA Method # (continuous real-time) I2-hr
Breathing zone sample height
Inhalable (<100iJ,m) I/O air lOM personal sampler. Analyze each 2 L/min -5 hr (600L) 30 ug / 50 ug/m’
thoracic (<10pm) fraction for asbestos,(TEM), and for
respirable (<4p.m) crystalline silica, gypsum, fiberglass
calcite (XRD)
Respirable I/O air NIOSH 7500 2.5 L/min-5.3 hr(800L) 5 ug / 6 ug/m’ s
crystalline silica
pl-l I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g 5
asbestos I/O dust PLM, andif<l%TEM I
H
silica, gypsum, I/O dust XRD
gypsum, fiber
glass, calcite
n
9 3
s
n
o
r
CO
NYC-WTC_000250554