| Sylvia Pry,ce - wtc resioential sampling plan oct15 1.doc Page 91
Sample/Analvtical Methods [NOTE: screening levels dictate detection/quantitation limit needs)
Parameter EnvironmentaLMedia Sampling/Analytical Method Sample Flow/time Analytical LOP / LOO*
Asbestos I/O" air NIOSH 7400, NIOSH 7402 16L/min-4hr(3840L) 0010Vcc(LOQ)
Breathing zone sample height 5 hr (4800L) 0.008 free
6hr(5760L) 0.007 free
Total Suspended O air EPA Method # (continuous realtime) 24-hr
Particulates Breathing zone sample height
PM10andPM2.5 Oair EPA Method # (continuous real-time) 24-hr
Breathing zone sample height
Inhalable (<100(im) VO air lOM personal sampler Analyze each 2 L/min -5 hr (600L) 30 ug / 50 ug/m’
thoracic (<10pm) fraction for asbestos,(TEM), and for
respirable (<4pm) crystalline silica, gypsum, fiberglass
caJcite (XRD)
Respirable I/O air NIOSH 7500 2.5 L/miii-5.3 hr(800L) 5ug/6ug/m’
crystalline silica
pH VO dust EPA SW 846 Mtd 9045C (soils) 10-25 g
asbestos VO dust PLM, and if<l%TF,M
asbestos, gypsum, VO dust XRD
mica, fiberglass
calcite
9