Indoor floor dust samples will be collected using EPA’s Environmental Response Team (ERT)
SOP for household dust collection (attached). As much dust as possible will be collected; the
area vacuumed will be measured and reported. Samples will be analyzed for asbestos, crystalline
silica, gypsum, mica, fiberglass and calcite using XRD. The pH of the dust will be tested using
EPA SW846 Method 9045C.
2. Exterior
Outdoor air and settled dust sampling will occur in areas adjacent to the residential building
being tested indoors. Sampling will occur concurrently with indoor sampling.
Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be
conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent
filter analysis using NIOSH 7402 to determine the amount of asbestos fibers present. Respirable
crystalline silica will be sampled and analyzed using NIOSH method 7500. Twenty four-hour
real-time TSP, PM 10 and PM 2.5 sampling will be conducted-again at breathing zone height.
Settled surface dust samples will be collected by scraping visible dust into a glass container. A
minimum of 25-30 grams of sample is required. Samples will be analyzed for asbestos,
crystalline silica, gypsum, mica, fiberglass and calcite using XRD. The pH of the dust will be
tested using EPA SW846 Method 9045C.