NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

WTC residential sampling plan draft, Oct 2001

Machine-extracted title · confidence 95%

Draft environmental sampling protocol for residential areas near the World Trade Center developed by ATSDR/DHAC in October 2001.

NYC-WTC_000235065–000235077
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

|Sy)vS Pryce - wtc residential sampling plan oct15 1 .doc Page 71

V. Residence Selection/Sampling Rationale

The selection of residential sampling locations will be decided upon by NYC DOH. The NYCDOH approach is described as follows: Approximately 60 residential imits will be sampled. A series of three concentric circles is being drawn around the WTC location. These circles will be divided into North, South, and East transects. Approximately three residential buildings will be selected for testing from within each area. ‘

Testing locations will mainly focused on occupied residences. However, approximately five unoccupied units nearest the WTC will be targeted for testing. In addition, approximately ten units will be selected outside of the concentric circles, in neighboring boroughs, to serve as background sample locations.

It should be noted that contaminant/materials of concern may vary as the distance of the residence increases from the WTC.

All samples collected, unless analyzed using destructive methods, will be archived until further notice.

VI. Sampling/Analvsis Approach:

1. Interior Air and dust sampling will focus on both common/high traffic areas of the building (e.g., lobbies, front entryways) and on a selected number of apartments/units in the building. Attempts will be made to select apartments/units where visible dust is and is not reported. Selecting entryways and common areas should be representative of worst case conditions for contaminant/material track-in fi'om outdoors. Selecting apartments/units in the same building should provide information the ranges found in indoor living spaces.

If the building is unoccupied, aggressive (leaf blower, high-power fan) indoor air sampling should be conducted. If the building is occupied, air sampling should be conducted with the building/unit HVAC system in continuous operation. After sampling is completed, filters for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter replacement.

Indoor air sampling for asbestos will be conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent filter analysis using NIOSH 7402 to determine if the fibers present are asbestos. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size particles will be conducted using the lOM sampler. The relative amounts (percent weight) of each fraction present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using XRD.

7

CONFIDENTIAL, CITY_21MC100_003382612 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000235071

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235071Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →