NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗DOH page showing page 1 of sampling protocol for WTC residential areas.
NYC-WTC_000250606–000250616OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
V. Residence Selection/Sampling Rationale
The selection of residential sampling locations will be decided upon by NYC DOH. The NYCDOH approach is described as follows: Approximately 60 residential units will be sampled. A series of three concentric circles is being drawn around the WTC location. These circles will be divided into North, South, and East transects. Approximately three residential buildings will be selected for testing fi-om within each area.
Testing locations will mainly focused on occupied residences. However, approximately three to five unoccupied and uncleaned units nearest the WTC will be targeted for testing. In addition, approximately ten units will be selected outside of the concentric circles, in neighboring boroughs, to serve as background sample locations.
It should be noted that contaminant/materials of concern may vary as the distance of the residence increases from the WTC.
All samples collected, unless analyzed using destructive methods, will be archived until further notice.
VI. Sampling/Analysis Approach:
1. Interior Air and dust sampling will focus on a selected number of apartments/units in the building. Attempts will be made to select apartments/units where visible dust is and is not reported. Selecting apartments/units in the same building should provide information the ranges found in indoor living spaces.
If the residential uni t is unoccupied, aggressive (leaf blower, high-power fan) indoor air sampling should be conducted. Only sampling personnel should be present in the residential unit when sampling is taking place. All sampling personnel should wear personal protective equipment including full face respirator with particulate filters, Tyvex suit, gloves and booties.
If the residential unit is occupied, air sampling should be conducted with the building/unit HVAC system in continuous operation. After sampling is completed, filters for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter replacement.
Indoor air sampling for asbestos will be conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent filter analysis using NIOSH 7402 to determine if the fibers present are asbestos. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size particles will be conducted using the lOM sampler. The relative amounts (percent weight) of each fi-action present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using XRD.
Indoor floor dust samples will be collected using EPA’s Environmental Response Team (ERT)
Page 6 of 11
CITY_21MC100_013489491 NYC-WTC_00025061 1
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320050
Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
13 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153241
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153241
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241933
Draft ambient sampling protocol for WTC-related fiber and dust exposure assessments.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similar indexed content
NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
Similar indexed content
NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
Similar indexed content
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similar indexed content
NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
Similar indexed content