****DR4FT Version 10, October 29, 2001

V. Residence Selection/Sampling Rationale

The selection of residential sampling locations will be decided upon by NYC DOH. The general NYCDOH approach is described as follows: A total of approximately 60 residential units will be sampled (a unit is an individual apartment or a common area in a multi-apartment building). A series of three concentric circles is being drawn around the WTC location. These circles will be divided by direction or zone from the WTC (north, south and west, and east). From five to seven of the multi-residential buildings will be selected for testing from within each zone.

Testing locations will mainly focus on occupied residences. However, approximately five unoccupied units nearest the WTC will be targeted for testing. In addition, appro.ximately ten units win be selected outside of the concentric circles, in neighboring boroughs or communities, to serve as background sample locations.

Sanrpling personnel will document the rationale for selecting buildings and residential units for sampling. They will also document sample locations, conditions during sampUng, and possible interfering factors (e.g., traffic, construction). In addition, unit occupants and building owner/operators will be requested to provide information that will better assist in evaluating the results. Section VII of this plan contains the information needed/requested.

It should be noted that types of contaminant/materials and their concentrations may vary as the s distance of tire residence from the WTC increases.

VI. Sampling/Analvsis Approach:

1. Indoor

Air and dust sampling wiU focus on both common/high traffic areas of the building (e.g., lobbies, Iront entryways) and on a selected number of apartments/units in the building. Attempts will be made to select apartments/units where dust is visible as well as units where dust is not visible. Selecting entryways and common areas should be representative of worst case conditions for contaminant/material track-in from outdoors. Selecting several apartments/units in the same building-with and without visible dust—should provide information on the ranges of contaminants found in indoor Using spaces.

If the building is unoccupied, aggressive (leaf blower, high-power fan) indoor air sampling should be conducted. If the building is occupied, air sampling should be conducted with the building/unit HVAC system’s fan in continuous operation. After sampling is completed, filters for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter replacement.

Indoor air sampling for asbestos will be conducted and analyzed using NIOSH method 7400. If an

7

CITY_21MC1OO_OO898645O

NYC-WTC_000338196

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338196Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →