NYC 9/11 Public Portal Document
iwtc residential plan oct29.wpd PageSj
I
****DRAFT yersion 10, October 29, 2001****
action level is exceeded subsequent filter analysis using NIOSH 7402 to determine if the fibers
present are asbestos will be conducted. Respirable crystalline silica will be sampled and analyzed
using NIOSH method 7500. Air sampling for inlialable, thoracic, and respirable size particles will
be conducted using the lOM™ sampler. The relative amounts (percent weight) of each fraction
present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and
calcite using X-ray diffraction (XRD) analysis. I
I
Indoor floor dust samples will be collected using the EPA ERT SOP for household dust
collection. As much dust as possible will be collected; the area vacuumed w'ill be measured and
reported. Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using
XRD. Asbestos will be analyzed using NIOSH Method 9002 (PLM); if <1% is found, TEM
analysis will be conducted. The pH of the dust will be tested using EPA SW846 Method 9045C.
2. Outdoor
Outdoor air and settled dust sampling will occur in areas adjacent to the residential building being
tested indoors. Sampling will occur concunently with indoor sampling.
Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be
conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent
filter analysis using NIOSH 7402 to determine the amount of asbestos fibers present will be
conducted. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500.
Air sampling for inhalable, thoracic, and respirable size particles will be conducted using the
lOM™ sampler. The relative amounts (percent weight) of each fraction present will be
determined. Each fraction will be analyzed for silica, gypsmn, mica, fiberglass, and calcite using
X-ray diffraction (XRD) analysis.
I
ON HOLD? Twelve-hour, continuous, real-time TSP, PMIO and PM 2.5 sampling will be
conducted-again at breathing zone height.
Settled surface dust samples will be collected by scraping visible dust into a glass container. A
minimum of 25-30 grams of sample is required. Samples will be analyzed for crystalline silica,
gypsum, mica, fiberglass and calcite using XRD, and for asbestos using NIOSH Method 9002
(PLM). If PLM shows less than <1%, analyze for asbestos using TEM. The pH of the dust will
be tested using EPA SW846 Method 9045C.
8
CITY_21MC100_008986451
NYC-WTC_000338197
OCR can misread numbers and units. Confirm readings against the page image before using them.