NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Chain-of-Custody: Ambient dust evaluations near WTC, Nov 9 2001

Machine-extracted title · confidence 54%

Final draft of ambient and indoor dust evaluation protocol for WTC area.

NYC-WTC_000250451–000250460
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

****FINAL DRAFT (Version 11), November 9, 2001****

Indoor floor dust samples will be collected using the EPA ERT SOP for household dust collection. As much dust as possible will be collected; the area vacuumed will be measured and reported. Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD analysis. Asbestos will be analyzed using MOSH Method 9002 (PLM); if <1% is found, TEM analysis will be conducted. The pH of the dust will be tested using EPA SW846 Method 9045C.

2. Outdoor

Outdoor air and settled dust sampling will occur in areas adjacent to the residential building being tested indoors. Sampling will occur concurrently with indoor sampling.

Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be conducted and analyzed using MOSH methods 7400 and 7402. Respirable crystalline silica will be sampled and analyzed using MOSH method 7500. Air sampling for inhalable and thoracic size particles will be conducted using EPA method IP-IOA. The respirable silica sample will be used to analyze the respirable fraction of the dust. The relative amounts (percent weight) of each fraction present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using XRD analysis.

Settled surface dust samples will be collected by scraping visible dust into a glass container. A minimum of 25-30 grams of sample is required. The area of the surface sampled (e.g., 100 cm^) will be measured and documented. Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD analysis, and for asbestos using MOSH Method 9002 (PLM). If PLM shows less than <1%, analyze for asbestos using TEM. The pH of the dust will be tested using EPA SW846 Method 9045C.

Page 6 of 41

CITY_21MC100_013489245 NYC-WTC_000250456

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250456Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000153241 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

Compare copies and versions →