****FJNAL draft (Version 11), November 9, 2001****

Sample/Analytical Methods

Parameter Environmental.Media Sampling/Analytical Method Sample Flow/time Analytical LOP / LOO*

Asbestos** VO*** air NIOSH 7400, NIOSH 7402 16 L/min-4 hr (3840L) 0.010 Vcc (LOQ) Breathing zone sample height 5 hr (4800L) 0.008 Vcc 6 hr (5760L) 0.007 Vcc

Inhalable (<100gm) I/O air ACGIH/ISO sampling criteria 4 L/min-3.2 hr (750L) 30 ug /40 ug/m’ particles Gravimetric and XRD (crystalline silica, gypsum, fiberglass, mica, and calcite)

Thoracic (<10pm) EPA IP-1 OA/Gravimetric and XRD 4L/min - 3.2 hr (750L) 30 ug/ 40 ug/m^ particles (crystalline silica, gypsum, fiberglass, mica, and calcite)

Respirable I/O air NIOSH 7500 2.5 L/min-5.3 hr(800L) 5 ug / 6 ug/m’ crystalline silica and respirable (<4pm) Gravimetric and XRD (gypsum, 30ug/90 ug/m’ particles fiberglass, mica, and calcite)

pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g

asbestos I/O dust NIOSH 9002 (PLM) and if <1% TEM

silica, gypsum, I/O dust XRD fiberglass, mica, and calcite

LOD:Limit of analytical detection; LOQ: Limit of analytical quantitation ** use professional judgement re: asbestos sampling times to avoid filter overload (collection of 2 samples with different sampling times may be necessary)

Page 7 of 41

NYC-WTC_000250897

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250897Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →