NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 14 pages

Final report draft: airborne/dust exposure

Machine-extracted title · confidence 36%

Draft final report assessing potential exposures to airborne and settled dust.

NYC-WTC_000320601–000320614
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

IrNancyJeffery - Residential Sampling Anal Report Draft 4_01.wpd Page

Draft: Do not Cite, Quote, or Release April 1, 2002

samples, no outside settled dust samples, 3 common areas with both settled dust and air, and 5 residential units with both settled dust and air.

Thirty air samples were taken from 29 different common areas.

Sample Analysis Indoor air sampling for asbestos was conducted and analyzed using NIOSH methods 7400 and 7402. Respirable crystalline silica was sampled and analyzed using NIOSH method 7500. Air sampling for inhalable and thoracic size particles was conducted using EPA method EP-IOA. The respirable silica sample was used to analyze the respirable fraction of the dust. The relative amounts (percent weight) of each fraction present was determined. Each fraction was analyzed for silica, gypsum, mica, fiberglass, and calcite using X-ray diffraction (XRD) analysis.

Indoor floor dust samples was collected using the EPA ERT SOP for household dust collection. As much dust as possible was collected; the area vacuumed was measured and reported. Samples was analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD analysis. Asbestos was analyzed using NIOSH Method 9002 (PLM); if <1% is found, TEM analysis was conducted. The pH of the dust was tested using EPA SW846 Method 9045C.

Ambient air sampling was conducted at breathing height. Air sampling for asbestos was conducted and analyzed using NIOSH methods 7400 and 7402. Respirable crystalline silica was sampled and analyzed using NIOSH method 7500. Air sampling for inhalable and thoracic size particles was conducted using EPA method IP-IOA. The respirable silica sample was used to analyze the respirable fraction of the dust. The relative amounts (percent weight) of each fraction present was determined. Each fraction was analyzed for silica, gypsum, mica, fiberglass, and calcite using XRD analysis.

Settled surface dust samples was collected by scraping visible dust into a glass container. A minimum of 25-30 grams of sample is required. The area of the surface sampled (e.g., 100 cm^) was measured and documented. Samples was analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD analysis, and for asbestos using NIOSH Method 9002 (PLM). If PLM shows less than <1%, analyze for asbestos using TEM. The pH of the dust was tested using EPA SW846 Method 9045C.

Participant Notification Each participant who allowed sampling in their home was provided with their individual results through a letter from the New York City Department of Health. Each building owner/operator was given results of all sampling conducting in the

CITY_21MC100_006729683

NYC-WTC_000320607

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320607Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →