AMBIENT AIR AND DUSTSAMPUNG PROTOCOL for H.S. for Leadership and Public Seivices (M894) Page 3 of 8

• Collect approximately 140 real-time environmental measurements of respirable particulates (PM2.5).

EVALUATION CRITERIA:

Since, there are no regulatory standards for indoor air quality in non-industriai buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

___________________ ______________ I IV./I

Temperature (T) Summer: 73-79T at 50% RH ASHRAE 55 Winter 68-75°F at 50% RH Relative Humidity (RH) 30 - 60 % ASHRAE 55 Carbon Dioxide (CO2) ^TOO-partsperrniHiorT^ppr^ ASHRAE 62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in ICO)____________ ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PM2.s) meter of air (pg/m^) 24-hour average______________ 40 pg/m^ 24-hour average USEPA - Recommendation for sensitive individuals such as asthmatic people and I children USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association ASHRAE = American Society of Heating, Refrigerating, and Air-Conditioning Engineers

Results from samples collected each day shall be reported verbally, no later than 11am the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.

In the event that real-time measurements of Temperature, Relative Humidity, and/or CO2 exceed the cited Target Guidelines, the following actions are to be taken:

CITY_21 MC100_014598096

NYC-WTC_000250256

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250256Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PS 89M lab report, 2002 · page 5

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similarity score 0.989 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →