NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Ambient air protocol, H.S. for Leadership & [name], 2003

Machine-extracted title · confidence 55%

Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).

NYC-WTC_000385871–000385878
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL fcr H.S. far Leadership and Public Services :MS54) Page 3 of 8

• Collect approximately 140 real-time environmental measurements of respirable particulates (PM2.5).

EVA LUA T/ON CRITERIA:

Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Socieiiy of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE): Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA),

TARGfET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

PARAMETER

Temperature (T) Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity (RH) 30-60% ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAEE62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in ICCD)____________ ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PIVks) meter of air (jig/m^) 24-hour average 40 ug/m^ 24-hour average USEPA - FEecommencafon for sensitive individuals such as asthmatic people and children

USEPA = United States Environmental Protection Agency NPAACiS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association ASHRAE = Ameriran Society of Heating, Refrigerating, and Air-Conditioning Engineers

Results from samples collected each day shall be reported verbally, no later than ,11am the next day, to E30E, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.

In the event that real-time measurements of Temperature, Relative Humidity, and/or CO? exceed the cited Target Guidelines, the following actions are to be taken:

CITY_21MC100_009214821

NYC-WTC_000385873

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385873Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →