Ambient air protocol, H.S. Economics and Finance, M 833

Machine-extracted title · confidence 60%

Ambient air protocol for H.S. Economics and Finance following WTC cleanup.

NYC-WTC_000385892–000385899
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Finance Page 3 of 8

Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation-for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHR/kE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Temperature (T) Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH F^elative Humidity (RH) 30 - 60 % ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE 62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PMzs) meter of air (gg/m^) 24-hour average 40 jig/m^ 24-hour average USEPA - Recommendation for sensitive individuals such as asthmatic people and children

USEPA = United Slates Environmental Protection Agency NP/\AQS = National Primary Ambient-Air Quality Standard AIHA = Amenrar Industrial Hygiene Association ASHRAE = American Society of Heating, Refrigerating, and Air-Conditioning Engineers

Results from samples collected each day shall be reported verbally, no later than 11 am the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.

In the event that real-time measurements of Temperature, Relative Humidity, and/or CO2 exceed the cited Target Guidelines, the following actions are to be taken:

1. Building engineering controls shall be adjusted and/or implemented to improve conditions.

CITY_21MC100_009223845

NYC-WTC_000385894

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385894Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PS 89M lab report, 2002 · page 5

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similarity score 0.998 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385905

Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.

Similar indexed content

Compare copies and versions →