NYC-WTC_000385905
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Ambient air protocol for H.S. Economics and Finance following WTC cleanup.
NYC-WTC_000385892–000385899OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Finance Page 3 of 8
Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:
Ventilation-for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHR/kE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED
PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Temperature (T) Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH F^elative Humidity (RH) 30 - 60 % ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE 62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PMzs) meter of air (gg/m^) 24-hour average 40 jig/m^ 24-hour average USEPA - Recommendation for sensitive individuals such as asthmatic people and children
USEPA = United Slates Environmental Protection Agency NP/\AQS = National Primary Ambient-Air Quality Standard AIHA = Amenrar Industrial Hygiene Association ASHRAE = American Society of Heating, Refrigerating, and Air-Conditioning Engineers
Results from samples collected each day shall be reported verbally, no later than 11 am the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.
In the event that real-time measurements of Temperature, Relative Humidity, and/or CO2 exceed the cited Target Guidelines, the following actions are to be taken:
1. Building engineering controls shall be adjusted and/or implemented to improve conditions.
CITY_21MC100_009223845
NYC-WTC_000385894
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000385905
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200222
Draft protocol establishing daily ambient air and dust monitoring procedures for asbestos contamination at the school.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
16 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324151
Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453730
Draft ambient air and dust sampling protocol for IAQ/asbestos monitoring at PS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234651
Draft protocol document outlining daily asbestos testing procedures for ambient air at P.S./I.S. 89 Manhattan following the WTC tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236871
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236904
Draft protocol for daily ambient air and dust sampling at P.S./I.S. 89 to monitor potential asbestos contamination.
16 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236847
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000385905
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250241
Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453730
Draft ambient air and dust sampling protocol for IAQ/asbestos monitoring at PS 89 Manhattan.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200222
Draft protocol establishing daily ambient air and dust monitoring procedures for asbestos contamination at the school.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236871
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
Similar indexed content
NYC-WTC_000200222
Draft protocol establishing daily ambient air and dust monitoring procedures for asbestos contamination at the school.
Similar indexed content
NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
Similar indexed content
NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
Similar indexed content
NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
Similar indexed content