AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS/IS89M. Page 3 of 8

EVALUATION CRITERIA:

Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

PARAMETER ________________ \ TARGET LEVEL ____________________ ■ ■Illi ■III AGENCY OR ORGANIZATION ■ ■III Temperature (T) Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity (RH) 30-60% ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE 62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in ICO)____________ ASHRAE 62)____________ Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PMas) meter of air (gg/m^) USEPA = United States Environmental Protection Agency NPAAQS = National PrimaryAmbient-Air Quality Standard AIHA = American Industrial Hygiene Association ASHRAE = American Society of Heating, Refrigerating, and Air-Conditioning Engineers

Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.

In the event that real-time measurements of Temperature, Relative Humidity, and/or CO2 exceed the cited Target Guidelines, the following actions are to be taken:

1. Building engineering controls shall be adjusted and/or implemented to improve conditions. In the event, that real-time measurements of respirable particulates exceed the cited Target Guidelines, BOE will immediately notify the UFT. the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

NYC-WTC_000236873

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000236873Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PS 89M lab report, 2002 · page 5

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similarity score 0.995 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →