AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. for Leadership and Public Sen/ices (M894) Page 4 of 8

1. Building engineering controls shall be adjusted and/or implemented to improve conditions. In the event, that real-time measurements of respirable particulates exceed the cited Target Guidelines, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event, that CO inside the school measured above the cited Target Guidelines (9ppm), BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event that real-time measurement(s) of CO inside the school is/are greater than 5ppm and less than 9ppm, BOE will identify the source and assess the situation.

In the event that real-time measurement(s) of TVOC inside the school is/are above the cited Target Guidelines (Ippm), BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event that real-time measurement(s) of 0.5 ppm of TVOC are obtained inside the school BOE will notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s)

ADDITIONAL TESTING

In addition to the above, once per week, preferably on Thursday, sampling settled dust for fiberglass, lead, and silica; wipe sampling for dioxin and PCB and air sampling, for heavy metals, and TVOCs shall be performed as follows:

SETTLED FIBERGLASS

• First floor lobby outside Auditorium - one sample.

• Cafeteria - one sample.

Auditorium - one sample

Two random classrooms - one sample from each classroom

• Third floor Hallway - one sample

• Fifth floor Hallway - one sample

• Seventh floor Hallway - one sample

• Ninth floor Hallway - one sample

CITY_21 MC100_014598097

NYC-WTC_000250257

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250257Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →