4
Various Locations /Manhattan ATC Proiect No. 15-19125-0314
1
TARGET GUIDELINES POR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic
Particulates meter of air (gg/m^) 24 hour USEPA NPAAQS
(PMxs) average
Respirable USEPA recommendation
Particulates 40 gg/m’ 24 hour average for children/sensitive
(PMa.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11**! Street to East 33"* Street. The
measurements were made from 5:50 A.M. to 4:41 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2 5 concentrations ranged from 17 gg/m^ to 84 gg/m^ with an
average of 39 gg/m®. The indoor concentrations ranged from 15 gg/m^ to 56
gg/m3 with an average of 26 gg/m3. All of the indoor readings were below the
NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5
micrometers or less in aerodynamic diameter. Ten (10) of the outdoor and six
(6) of the indoor readings were above the USEPA recommended guideline for
children and sensitive individuals of 40 gg/m3. Ten of the outdoor readings
were also above the 65 gg/m^ 24-hour average concentration of particulate
matter 2.5 micrometers or less in aerodynamic diameter
These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, all of indoor readings were below the NPAAQS of
65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers
or less in aerodynamic diameter. Ten (10) of the outdoor and six (6) of the
indoor readings were above the USEPA recommended guideline for children
and sensitive individuals of 40 gg/m^. Ten of the outdoor readings were also
above the 65 gg/m3 24-hour average concentration of particulate matter 2.5
micrometers or less in aerodynamic diameter
It is our pleasure to provide these air quality consultative services to the New-
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ASSOCIAJSS M ^ed by:
Yiannis Efsta^iou CTamcs R. CoKn, CIHTcsP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMCl00_003422579
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239863