NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 18, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES POR AIR QUALITY PARAMETERS EVALUATED*
PARA«n:R.~
Respirable 65 micrograms per cubic
Particulates meter of air (pg/ m3) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 (xg/m3 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11 th Street to East 33"’ Street. The
measurements were made from 5:43 A.M. to 4:28 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 32 pg/m^ to 68 pg/m3 with an
average of 47 pg/m^. The indoor concentrations ranged from 23 gg/m^ to 53
gg/m3 with an average of 36 pg/m3. Two (2) of the outdoor readings were above
the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter
2.5 micrometers or less in aerodynamic diameter. Twenty-two (22) of the
outdoor readings and thirteen (13) of the indoor readings were above the
USEPA recommended guideline for children and sensitive individuals of 40
pg/m3.
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, two (2) of the outdoor readings were above the
NPAAQS of 65 |tg/m3 24-hour average concentration of particulate matter 2.5
micrometers or less in aerodynamic diameter. Twenty-two (22) of the outdoor
readings and thirteen (13) of the indoor readings were above the USEPA
recommended guideline for children and sensitive individuals of 40 pg/m’.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education, If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211,
Sincerely,
ATC ASSOCIATES INC.
< <2. l -
Yiannis EfstatHiou "Barnes R. Cohn, ClH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMCl00_003422895
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239923
OCR can misread numbers and units. Confirm readings against the page image before using them.