NYC 9/11 Public Portal Document
a Mr. Bernard P. Orlan May 28, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
PARAMETER
Respirable 65 micrograms per cubic
Particulates meter of air (pg/ms) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 )ig/m3 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11*** Street to East 33^3 Street, The
measurements were made from 5:51 A,M. to 4:31 P,M, The lAQ field report
forms are provided as the Attachment,
The outdoor PM2.5 concentrations ranged from 66 pg/m^ to 98 pg/m3 with an
average of 86 pg/m^. The indoor concentrations ranged from 21 pg/m^ to 71
pg/m3 with an average of 56 pg/nP. Seven (7) of the indoor and all of the
outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average
concentration of particulate matter 2.5 micrometers or less in aerodynamic
diameter. Twenty-eight (28) of the indoor and all of the outdoor readings were
above the USEPA recommended guideline for children and sensitive individuals
of 40 pg/m3.
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, seven (7) of the indoor and all of the outdoor
readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of
particulate matter 2.5 micrometers or less in aerodynamic diameter. Twenty
eight (28) of the indoor and all of the outdoor readings were above the USEPA
recommended guideline for children and sensitive individuals of 40 pg/m^.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATCyASSOClATES INC. Reviewed by:
AuSerJaval^ James R. Cohn, CIH, CSP
Senior Pro/e/t Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMCl0 0_003422749
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239895