NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 12,2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 gg/m^ 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11^^ Street to East 33«< Street. The
measurements were made from 5:53 A.M. to 4:31 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 93 pg/m^ to 161 pg/m" with an
average of 126 pg/m-V The indoor concentrations ranged from 41 pg/m^ to 122
pg/m3 with an average of 88 pg/m-L All of the outdoor readings and twenty-five
(25) of the indoor readings were above the NPAAQS of 65 pg/m^ 24-hour
average concentration of particulate matter 2.5 micrometers or less in
aerodynamic diameter. All thirty-one (31) of the indoor readings and all thirty-
four (34) of the outdoor readings were above the USEPA recommended
guideline for children and sensitive individuals of 40 pg/m^.
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, aU of the outdoor readings and twenty-five (25) of
the indoor readings were above the NPAAQS of 65 pg/m^ 24-hour average
concentration of particulate matter 2.5 micrometers or less in aerodynamic
diameter. All thirty-one (31) of the indoor readings and all thirty-four (34) of
the outdoor readings were above the USEPA recommended guideline for
children and sensitive individuals of 40 pg/m^.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC. R(
-/
iannis Efstatniou James R. Cohn,
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003422855
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239915
OCR can misread numbers and units. Confirm readings against the page image before using them.