Air monitoring report, NYC schools, May 2002

Machine-extracted title · confidence 95%

ATC Associates report on respirable particulate air monitoring at NYC Board of Education locations for lower Manhattan comparison.

NYC-WTC_000239900–000239901
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan May 31, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314 TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* AGENCY Respirable 65 micrograms per cubic Particulates meter of air (gg/m^) 24 hour USEPA NPAAQS (PMa.5) average Respirable USEPA recommendation Particulates 40 ng/m3 24 hour average for children/sensitive (PM3.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from twenty-nine (29) school locations in Manhattan, ranging from West 11* Street to East 33'’'' Street. The measurements were made from 5:46 A.M, to 4:30 P.M, The lAQ field report forms are provided as the Attachment,

The outdoor PM2.5 concentrations ranged from 51 pg/m^ to 123 pg/m^ with an average of 91 pg/m^. The indoor concentrations ranged from 34 pg/m^ to 106 p,g/m3 with an average of 71 ug/mC Twenty-one (21) of the indoor and twenty­ eight (28) of the outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Twenty-nine (29) of the indoor and all of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.

These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION Based on our measurements, twenty-one (21) of the indoor and twenty-eight (28) of the outdoor readings were above the NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Twenty-nine (29) of the indoor and all of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 ng/mC

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC^SSOCIATES INC. Reyi

^el James R. Cohn, CIH, CSP ;nior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003422779 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239901

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239901Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →