Mr. Bernard P. Orlan June 19, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic
Particulates meter of air (gg/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11<** Street to East 33"> Street. The
measurements were made from 5:52 A.M. to 4:37 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 63 gg/m^ to 115 gg/m^ with an
average of 88 gg/m^. The indoor concentrations ranged from 37 gg/m^ to 87
gg/m3 with an average of 66 gg/m^. Seventeen (17) of the indoor and thirty-
three (33) of the outdoor readings were above the NPAAQS of 65 gg/m^ 24-hour
average concentration of particulate matter 2.5 micrometers or less in
aerodynamic diameter. All thirty-four (34) of the outdoor readings and thirty
(30) of the indoor readings were above the USEPA recommended guideline for
children and sensitive individuals of 40 gg/m3.
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, seventeen (17) of the indoor and thirty-three (33)
of the outdoor readings were above the NPAAQS of 65 gg/m^ 24-hour average
concentration of particulate matter 2.5 micrometers or less in aerodynamic
diameter. All thirty-four (34) of the outdoor readings and thirty (30) of the
indoor readings were above the USEPA recommended guideline for children
and sensitive individuals of 40 gg/m®.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC. Reviei A
Yiannis Efstathi James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMCI00_003422915
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239927