Mr, Bernard P. Orlan May 7, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* E. Respirable 65 micrograms per cubic Particulates meter of air (gg/m^) 24 hour USEPA NPAAQS (PM2.5) average Respirable USEPA recommendation Particulates 40 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard REAL-TIME SAMPLING RESULTS

Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from twenty-nine (29) school locations in Manhattan, ranging from West 11* Street to East 33"' Street. The measurements were made from 5:55 A.M. to 4:18 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 53 gg/m^ to 114 gg/m^ with an average of 87 gg/m^. The indoor concentrations ranged from 26 gg/m^ to 85 gg/m3 with an average of 59 gg/m3. Ten (10) of the indoor and twenty-nine (29) of the outdoor readings were above the NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Thirty (30) of the indoor and thirty-four (34) of the outdoor readings were above the USEPA recommended 'guideline for children and sensitive individuals of 40 gg/m^.

These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION Based on our measurements, ten (10) of the indoor and twenty-nine (29) of the outdoor readings were above the NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Thirty (30) of the indoor and thirty-four (34) of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 gg/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATP ASSOCIATES INC. Review

iannis Efstamiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_2IMCl00_003422609 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239869

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239869Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →