NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25.th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
LJ New York, NY 10010 Report Date: 09/28/01
f' I ASBESTOS FIBER TkMALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987 ,
Sample Identification Analysis Parameters
J . ■
Project/Site: 40 Rector Street, NY, NY . TEM Sample Nc.: 5574 - 59634
Floors 15-17
Date Received: 09/28/^ Grid Openings Analyzed: 6
Project Sample No.: T05 Average Grid Opening: 106.00 um
Air Volume: . 1310 liters Total Area Analyzed: 0.0674 mrn2
Filter Type Analytical Sensitivity:' 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/mS
Chrysotile Asbestos 0 1 0 1 2 1 29.7 0.0087 288
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 2 1 29.7 0.0087 288
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 2 ,1 29.7 0.0087 N/A
The estimated uncertainty, of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
o Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
f.T
Director of Electron Microscopy
I.J
NYC-WTC_000237272
OCR can misread numbers and units. Confirm readings against the page image before using them.