NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
n 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/29/01
ri ASBESTOS FIBER TU^ALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
■ With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52. No. 210, October 30, 1987
n Sample Identification Analysis Parameters
Project/Site; 40 Rector Street, RY, NY TEM Sample No.:. 5579 - 59741
Date Received: 09/29/31 Grid Openings Analyzed:_ _6
Project Sample No. :TT^ Average Grid Opening.- 105.00 um
Air Volume: 1280 liters Total Area Analyzed: 0.0574 mm2
’ '■ Filter Type: MCE 25 mm diam. , Pore Size: 0-.45 urn Analytical Sensitivity: 14.8 s/mm2
Bffective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 , 0 0 0 0 0 0.0 0 . 0000 0
Total asbestos {includes ambiguous structures) 0 0 0.0 0,0000 0
Non-Asbestos 0 0 •0 0 0 0 0.0 0.0000 K/A-
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
TUialyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237199