ATC Environmental, Inc. n 104 East 25th Street New York, New York 10010 ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 09/20/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

T Sample Identification Anaiysis Parameters

Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No. : Lobby & 16th Floor Date Received: 09/20/01 Grid Openings Analyzed:__ 4

Project Sample No.: 04 Average Grid Qpenincr: 106.00 um

Air Volume: 1800 liters Total Area Analyzed: 0.045Q mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity:22;2 s2mm2 Effective Area: 385 mm2 C.QQ48 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct. >=5um 5truct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.c 0. 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0 L.J

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Ncn-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for ths method.

Analyzed by: Report Reviewed by;

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy LJ

NYC-WTC_000174893

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174893Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos TEM analysis report, Sept 25, 2001

NYC-WTC_000174880

Laboratory report documenting asbestos fiber analysis by transmission electron microscopy for a site in New York on September 25, 2001.

Similar indexed content

Asbestos TEM analysis report, Sept 28, 2001

NYC-WTC_000174872

Laboratory report documenting asbestos fiber analysis by transmission electron microscopy for a site in New York on September 28, 2001.

Similar indexed content

Compare copies and versions →