NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code #1187
New York, NY 10010 Report Date: 09/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763) , Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: 5554 - 59465
Floors 19, 18, 10, 9, 8
Date Received: 09/24/01 Grid Openings Analyzed:__ 6
Project Sample No.: 09-24-24 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diatn. , Pore. Sizar 0.45 um Ana1ytica1 Sensitivity 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
■ fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ncrm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0.
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
I Non-Asbestos 0 0 0 0 0 0 0-0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (.^11 Structures) 0 0 0.0 o.ooco N/A
Ths estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by.
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000174880