NYC 9/11 Public Portal Document
ATC Environmental, Inc.
r'}
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/25/01
, J ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)'
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector Sb., NY, NY TEM Samble No.: 5554 59462
(" Floors 15, IS, 10, 9, 8
Date Received: 09/24/01 Grid Openings Analyzed:__ 6
Project Sample No.: C9-24-2I Average Grid Opening t • 1'06.00 um
Air Volume: 1330 liters Total Area Analyzed; 0.0674 mm2
' - Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytica1 Sensitivity:■ 14.8 s/mm2
: Effective Area: 385mm2 ' 0.0043 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total .
• Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0. 0 - 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Kon-Asbestos 0 0 0 0 0 .0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
' ■ Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
aJ
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
!. T Director of Electron Microscopy
NYC-WTC_000174879
OCR can misread numbers and units. Confirm readings against the page image before using them.