NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
!... I ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
_j With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1937
Sample Identification Analysis Parameters
[...., Project/Site: 40 Rector Street,40 Rector St^^j^y,NY TEM Sample No.: 5741 - 62008
P1oo£S1z12,14j_JJj_19
Date Received: 10/23m Grid Openings Analyzed:__ 4
Project Sample No.: 49-7 Average Grid Opening: 106.00 urn
Air Volume: 1800 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 2S mm diam., Pore Size: 0.4S um Analytical Sensitivity: 22.2 a/mm2
Effective Area: 385 mm2 0.0048 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filtc Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
: ’ Non-asbestos fiber i.d. (EDS/SAED): None detected
_j Amphibole Asbestos Type: None detected
ru The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000174903