NYC 9/11 Public Portal Document
ATC Environmental, Inc.
f.\
104 East 25th Street
New York, New York 10010
~ ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code #1187
New York, NY 10010 Report Date: 09/28/01
ASBESTOS FIBER TmALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
LJ Method; AHERA Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEM Sample No.: 5574 - 59636
1 Floors 15-17
Date Received: 09/28/01 Grid Openings Analyzed:__ 6
L.J
Project Sample No.: 707 Average Grid Opening': 106.00 urn
Air Volume: 1320 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385mm2 0.0043 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct =5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0..0000 -0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0-0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
l.J
n Analyzed by: Report Reviewed by;
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy