Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/ OSHA
Flow Air Fiber Fibers
SciLab Client ■ Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/9/O2-STEL-O338 3/9/02 2 30 60 100 4 5.10 < 0.045
Mike Green
02 GS-3/9/02-STEL-0339 3/9/02 2 30 60 100 1.5 1.91 <0.045
Wilson Bueno
03 GS-3/9/02-STEL-0340 3/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: I
04 GS-3/9/02-STEL-0341 3/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot be tr sammes (er
; olte Analyzed: 3/12/02
Analyzed by; Anthony Hinton
Samples analyzed by NIOSH Issue #2, //I IB/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq ram of filter area: ND=No fibers observed: NA=Not
Analyzed; Walton-Beckett graticle field area = 0.00785 :\WA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0,01 fibeN^ istanUard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology