SciLal^#: 202022971 Page- of ]•
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street, OSHA
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered pieUs pjbers Density Cone. TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-21902-STEL-0201 2/19/02 2 30 60 100 1 1.27 < 0.045
Wilfredo Ramirez
02 GS-21902-STEL-0202 2/19/02 2 30 60 100 1 1.27 <0.045
Ceasar Rodriguez
03 GS-21902-STEL-FB1 2/19/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-21902-STEL-FB2 2/19/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes;
(1) Fibers/cc cannot be/wLulatedfOT samil^for blanks) with no air volume.
Analyzed by; Marvin Brothers xC. ; Date Analyzed: 2/20/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticlc field area » 0.00785 mini: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainly of compliance with the O.Ol fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.