SciLa A #: 202032653
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (lixrs/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 OS-3/14/02-STEL-0354 3/14/02 2 30 60 100 16 12.74 0.082
Ceasar Rodriguez
02 GS-3/14/02-STEL-0355 3/14/02 2 30 60 100 2 2.55 <0.045
Fabian Pereyra
03 GS-3/14/02-STEL-0356 3/14/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
04 GS-3/14/02-STEL-0357 3/14/02 0 0 0 100 0.5 0.64
Blank Footnotes! I
Reporting Notes:
(1) Fibers/cc cannot be ci atwr^FBlanks) with no air volume.
Analyzed by; Tatyana Grimchak J ; Date Analyzed; 3/16/02
Samples analyzed by NIOSH 74(X)(A) MeflioCjsSie #2, 8/15/94: Limit of Detection= 5.S fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainly of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0,45, New York samples (NYSDOH ELAP Lab # 11480); Nadonal Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
o
H
t-o
s
o
KJ
Cn
Cn
(_n
co
(_n
NYC-WTC_000235406
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235406Source: NYC Law Department, mirrored locally