SciLa^b#: 202031111 of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (jiters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-2/28/02-STEL-0303 2/28/2002 2 30 60 100 6 7.64 0.049
Jose Adorino
02 GS-2/28/02-STEL-0304 2/28/2002 2 30 60 100 2 2.55 < 0.045
Ceasar Rodriguez
03 GS-2/28/02-STEL-B1 2/28/2002 0 0 0 100 0.5 0.64
Blank Footnotes: 1
04 GS-2/28/02-STEL-B2 2/28/2002 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be cddeok ti1;nilnp~ffrb no air volume.
Analyzed by: Anthony Hintoi^pfej] ry^pbate Analyzed: 3/1/2002
Samples analyzed by NIOSH 7400(A) Iv ssue #2, 8/13/94: Limit of Detection® 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field .00783 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limil (Employers Compliance Test)- Calculated as a one sided UCL lo
determine 95% certainty of compliance with the 0.01 fiber/x standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA #102843.
O
o
o
o
I
o
4^
cn
CD
o
o
CD
cn
NYC-WTC_000235648
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235648Source: NYC Law Department, mirrored locally