NYC 9/11 Public Portal Document
SciLa #: 202031392 Pag Of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/2/02-STEL-0314 3/2/02 2 30 60 100 2 2.55 <0.045
Loading Dock - East
02 GS-3/2/02-STEL-0315 3/2/02 2 30 60 too 1.5 1.91 ' < 0.045
Loading Dock - West
03 GS-3/2/02-STEL-0316 3/2/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-3/2/02-STEL-0317 3/2/02 0 0 0 100 0.5 0.64
Blank Footnotes: I
Reporting Notes:
(1) Fibers/cc cannot be calculaled/orj^ft^^^fblanks) with no air volume.
Analyzed by; Tatyana Grimchak*/' ; Date Analyzed: 3/5/02
Samples analyzed by NIOSH rtOWA/Method, Issue #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45. New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.