Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/ OSHA
Flow Air Fiber Fibers
SciLab Client • Rate Duration Filtered Fields Fibers Density Cone. TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/9/02-STEL-0338 3/9/02 2 30 60 100 4 5.10 < 0.045
Mike Green
02 GS-3/9/02-STEL-0339 3/9/02 2 30 60 100 1.5 1.91 < 0.045
Wilson Bueno
03 GS-3/9/02-STEL-0340 3/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
04 GS-3/9/02-STEL-0341 3/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: J
Reporting Notes:
(1) Fibers/cc cannot be
Analyzed by; Anthony Hinton _ /__ ; nite Analyzed; 3/12/02
Samples analyzed by NIOSH imil of Detections 5.5 fibers per 100 fields or 7 fibers/nim2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed; NA=Not
Analyzed; Walton-Beckett graticle field area = 0.00785 8 Hr TWA calculation assumes zero exposure for remainder of 3 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0,01 fil ; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not luced except in full without the approval of the laboratory. AIHA # 102843.
o
NJ
S
O
o
o
I
o
on
on
Cn
NYC-WTC_000235399
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235399Source: NYC Law Department, mirrored locally