NYC 9/11 Public Portal Document
Sci b#: 202031395 Pa 1 of i
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PGM) Fiber Results
35052-0000-00007; NYC Law Department; 100 Church St.
Flow Air Fiber Fibers
SciLab Client Date Ratg Duration Filtered Density Cone.
Sample # / Location
Fields Fibers TWA
Sample # Collected (Hters/min.) (min.) (liters) (Fibers/mra ) (Fibers/cc)
01 GS-3/4/02-OSHA-0311 3/4/02 2 300 600 NA
Wilson Bueno Footnotes: 5
02 GS-3/4/02-OSHA-0312 3/4/02 2 300 600 100 47.5 60.51 0.039
Miguel Reynoso Footnotes: 1
03 GS-3/4/02-OSHA-0313 3/4/02 2 300 600 NA
Wilson Bueno Footnotes: 3
04 GS-3/4/02-OSHA-0314 3/4/02 2 300 600 100 44 56.05 0.036
Miguel Reynoso
05 GS-3/4/02-OSHA-0315 3/4/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
06 GS-3/4/02-OSHA-0316 3/4/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
Reporting Notes:
(1) Moderate to heavy particulate matter is present on the filter which may obscure some fibers causing results with a low bias.
(2) Fibers/cc cannot be calculated for samples (or blanks) with no air volume.
(3) Analyst was unable to quan^fy fiberjeoncentration because of overloading of particulate material on the filter.
Analyzed by: Tatyana Grimchak ; Date Analyzed; 3/5702
Samples analyzed by NIOSH 7400(40 Methrajssue #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for rerminder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=O.4O5. Interlab Sr=0.45, Sew York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
o
H
to
(—1
S
O
o
o
I
o
CJ1
(JI
Ui
u-
NYC-WTC_000235303
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235303Source: NYC Law Department, mirrored locally